APPLICATIONS

Partitions and paneling , ceilings in public rooms and corridors, flow underlayment, computers rooms, furniture, bus bodies, railway coaches, milk booths, sign boards, insert in panel doors, storage racks.

TECHNICAL SPECIFICATION

Test Test Requirements of IS 303 BWR/MR Test Result
1 Moisture Contents 5-15% 6-10%
2 Gluie Adhesion
(a)Water Resistance test

(b) Mycological Test
Three cycle of 8 hours boiling in water and drying at

65+/-2°C for 16 hours, 3 hours at 60+/-2°C in water & drying
65+/-2°C for 8 hours.

one cycle of 21 days
Pass Standard

Pass Standard
3 Static Bending Strength
MOE (Modular of Elasticity)
Along
Avg. N/mm²
Min. Ind. N/mm²
5000/4000
4500/3600
5800/4700
5200/4200
4 Across Avg. N/mm²
Min. Ind. N/mm²
2500/2000
2200/1800
3200/2700
2800/2400
5 MOR (Modular of Rupture) Along Avg. N/mm²
Min. Ind. N/mm²
40/30
36/27
45/40
40/35
6 Across Avg. N/mm²
Min. Ind. N/mm²
20/15
18/13
30/25
25/20