APPLICATIONS

Factories and building, sewer construction, construction of swimming pool, bridge construction, exterior and general shuttering work, beams and every construction and foundation job.

TECHNICAL SPECIFICATION

S.No Test ISI Requirement Test Result
1 Moisture Contents 5-15% 8%
2 Glue Shear Strength tin dry condition (a) Individual 1100 Newton
(b) Average min. 1350
Newton 1470
Newton 1710
3 Newton Glue Shear Strength in wet
condition Adhesion of Piles (Knife test)
(a) Individual 800 Newton
(b) Average min. 1000 Newton
1370 Newton
1560 Newton
4 Glue Shear Strength mycological test Adhesion of Piles (Knife test) (a) Individual 800 Newton
(b) Average min. 1000 Newton
1350 Newton
1590 Newton
5 Tensile Strength
a. Parallel to grain direction
b. Right angle to grain direction
c. Sum of both directions
Min. 32.5 N/mm² 70.5 N/mm²
Min. 22.5 N/mm² 63.0 N/mm²
Min. 65.0 N/mm² 133.5 N/mm²
 
6 MOE
Parallel to grain
Perpendicular to grain
8000 N/mm²
4000 N/mm²
9563 N/mm²
7275 N/mm²

WE ARE CERTIFIED BY






Toll Free No:1800030002

Mobile No: +91-9896002222,+91-9996072323

© 2017 Black Cobra. All rights reserved.